The Robotics Institute
Search the site
RI | Publications | Peripherally Inserted Central Catheters by Nurses using the Sonic Flashlight

Text only version of this site

Peripherally Inserted Central Catheters by Nurses using the Sonic Flashlight
D.C. Wang, N.B. Amesur, R. Klatzky, A. Bayless, B. Mandella, C. Banks, G. Shukla, and G.D. Stetten
Clinical and Translational Science Day,, May, 2007.

Jump to: Download | Abstract | Notes | Text Reference | BibTeX Reference

Download [Help]

Adobe portable document format (pdf) [272 KB]

Copyright notice: This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder.

Abstract

Peripherally Inserted Central Catheters (PICCs) are often placed in patients requiring multiple doses of intravenous (IV) medicine or multiple draws of blood samples. These are commonly done by experienced nurses on the IV team, who travel throughout the hospital to place these lines at the patient’s bedsides (in lieu of a costly trip to the radiology department). PICC placement is ubiquitiously performed under ultrasound guidance, allowing the clinician visualization of the target vessel prior to needle puncture. We propose here the use of a new ultrasound device for guidance of PICC placement, and demonstrate its feasibility for use by IV team nurses on the hospital floors. We also demonstrate that IV team nurses can adapt to the SF quickly.

Notes

Associated centers: VASC, MRTC, SRI, and FRC
Associated labs/groups: Visualization and Image Analysis and Human-Robot Interaction Group
Associated project: Sonic FlashlightTM

Number of pages: 1

Text Reference

D.C. Wang, N.B. Amesur, R. Klatzky, A. Bayless, B. Mandella, C. Banks, G. Shukla, and G.D. Stetten, "Peripherally Inserted Central Catheters by Nurses using the Sonic Flashlight," Clinical and Translational Science Day,, May, 2007.

BibTeX Reference

@inproceedings{Wang_2007_5888,
   author = "David C Wang and N.B. Amesur and Roberta Klatzky and A. Bayless and B. Mandella and C. Banks and Gaurav Shukla and George D Stetten",
   title = "Peripherally Inserted Central Catheters by Nurses using the Sonic Flashlight",
   booktitle = "Clinical and Translational Science Day,",
   month = "May",
   year = "2007"
}


The Robotics Institute is part of the School of Computer Science, Carnegie Mellon University.
For updates and comments, please see these instructions.
This page maintained by robotwebmaster@ri.cmu.edu