Search

Navigator: RI | Publications | Psychophysical Evaluation of In-Situ Ultrasound Visualization

Graphics enhanced version of this site

Psychophysical Evaluation of In-Situ Ultrasound Visualization
B. Wu, R. Klatzky, D.M. Shelton, and G.D. Stetten
IEEE Transactions on Visualization and Computer Graphics (TVCG), Special Issue on Haptics, Virtual and Augmented Reality, Vol. 11, No. 6, November, 2005, pp. 1 - 10.

Jump to: Abstract | Notes | Text Reference | BibTeX Reference


Abstract

We present a novel psychophysical method for evaluating ultrasonography based on Real-Time Tomographic Reflection (RTTR), in comparison to Conventional Ultrasound (CUS). The method measures the user's perception of the location of an ultrasound-imaged target independently from assessing the action employed to reach it. Three experiments were conducted with the Sonic Flashlight (SF), an RTTR device, and CUS. The first two experiments determined subjects' perception of target location with a triangulation-by-pointing task. Depth perception with the SF was comparable to direct vision, while CUS caused considerable underestimation of target depth. Binocular depth information in the SF was shown to significantly contribute to its superiority. The third experiment tested subjects in an ultrasound-guided needle insertion task. Because the SF provides visualization of the target at its actual location, subjects performed insertions faster and more accurately by using the SF rather than CUS. Furthermore, the trajectory analysis showed that insertions with the SF generally went directly to the target along the desired path, while CUS often led to a large deviation from the correct path consistent with the observed underestimation of target depth. These findings lend great promise to the use of RTTR-based imaging in clinical practice and provide precise means of assessing efficacy.


Notes

Associated centers: VASC, MRTC, SRI, and FRC
Associated labs/groups: Human-Robot Interaction Group and Visualization and Image Analysis
Associated project: Sonic FlashlightTM

Number of pages: 10


Text Reference

B. Wu, R. Klatzky, D.M. Shelton, and G.D. Stetten, "Psychophysical Evaluation of In-Situ Ultrasound Visualization," IEEE Transactions on Visualization and Computer Graphics (TVCG), Special Issue on Haptics, Virtual and Augmented Reality, Vol. 11, No. 6, November, 2005, pp. 1 - 10.


BibTeX Reference

@article{Wu_2005_5263,
   author = "Bing Wu and Roberta Klatzky and Damion Michael Shelton and George D Stetten",
   title = "Psychophysical Evaluation of In-Situ Ultrasound Visualization",
   journal = "IEEE Transactions on Visualization and Computer Graphics (TVCG), Special Issue on Haptics, Virtual and Augmented Reality",
   month = "November",
   year = "2005",
   volume = "11",
   number = "6",
   pages = "1 - 10"
}


The Robotics Institute is part of the School of Computer Science, Carnegie Mellon University.