The Robotics Institute
Search the site
RI | Publications | Correlation of accelerometer and microphone data in the "coin tap test"

Text only version of this site

Correlation of accelerometer and microphone data in the "coin tap test"
H. Wu and M. Siegel
IEEE Transactions on Instrumentation and Measurement, Vol. 49, No. 3, June, 2000, pp. 493 - 497.

Jump to: Download | Abstract | Notes | Text Reference | BibTeX Reference

Download [Help]

Adobe portable document format (pdf) [107 KB]

Copyright notice: This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder.

Abstract

In the "coin tap test," an operator taps with a coin-like light tool on the structure to be inspected, feeling the subtle difference of impact force and hearing the resulting sound to discriminate defective regions from normal ones. The test remains largely subjective, and there has been considerable uncertainty about the physical principles behind it. Analyzing and comparing the force measured by an accelerometer in the hammer and the resulting sound recorded with a microphone, this paper seeks an understanding of the fundamental principles underlying the individual measurement techniques. It gives a paradigm for sensor fusion via using the data from one modality to select the optimal time window for signal analysis of another modality.

Notes

Associated center: CIMDS
Associated lab/group: Intelligent Sensor, Measurement, and Control Lab

Text Reference

H. Wu and M. Siegel, "Correlation of accelerometer and microphone data in the "coin tap test"," IEEE Transactions on Instrumentation and Measurement, Vol. 49, No. 3, June, 2000, pp. 493 - 497.

BibTeX Reference

@article{Wu_2000_3564,
   author = "Huadong Wu and Mel Siegel",
   title = "Correlation of accelerometer and microphone data in the "coin tap test"",
   journal = "IEEE Transactions on Instrumentation and Measurement",
   month = "June",
   year = "2000",
   volume = "49",
   number = "3",
   pages = "493 - 497"
}


The Robotics Institute is part of the School of Computer Science, Carnegie Mellon University.
For updates and comments, please see these instructions.
This page maintained by robotwebmaster@ri.cmu.edu