Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions

Yong-Lae Park, Santhi Elayaperumal, Bruce Daniel, Seok Chang Ryu, Mihye Shin, Joan Savall, Richard J. Black, Bezhad Moslehi, and Mark R. Cutkosky
IEEE/ASME Transactions on Mechatronics, Vol. 15, No. 6, December, 2010, pp. 906-915.


Download
  • Adobe portable document format (pdf) (1MB)
Copyright notice: This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder.

Abstract
We describe a MRI-compatible biopsy needle instrumented with optical fiber Bragg gratings for measuring bending deflections of the needle as it is inserted into tissues. During procedures, such as diagnostic biopsies and localized treatments, it is useful to track any tool deviation from the planned trajectory to minimize positioning errors and procedural complications. The goal is to display tool deflections in real time, with greater bandwidth and accuracy than when viewing the tool in MR images. A standard 18 ga × 15 cm inner needle is prepared using a fixture, and 350-um-deep grooves are created along its length. Optical fibers are embedded in the grooves. Two sets of sensors, located at different points along the needle, provide an estimate of the bent profile, as well as temperature compensation. Tests of the needle in a water bath showed that it produced no adverse imaging artifacts when used with the MR scanner.

Keywords
biomedical transducers, biopsy, Bragg gratings, magnetic resonance imaging (MRI), optical fiber sensors, strain measurement.

Notes
Number of pages: 10

Text Reference
Yong-Lae Park, Santhi Elayaperumal, Bruce Daniel, Seok Chang Ryu, Mihye Shin, Joan Savall, Richard J. Black, Bezhad Moslehi, and Mark R. Cutkosky, "Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions," IEEE/ASME Transactions on Mechatronics, Vol. 15, No. 6, December, 2010, pp. 906-915.

BibTeX Reference
@article{Park_2010_7491,
   author = "Yong-Lae Park and Santhi Elayaperumal and Bruce Daniel and Seok Chang Ryu and Mihye Shin and Joan Savall and Richard J. Black and Bezhad Moslehi and Mark R Cutkosky",
   title = "Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions",
   journal = "IEEE/ASME Transactions on Mechatronics",
   pages = "906-915",
   month = "December",
   year = "2010",
   volume = "15",
   number = "6",
}