Project Description
Digitized postoperative radiographs of the pelvis after total hip replacement are analyzed to measure the orientation of the artificial acetabular cup by matching the calculated projection to the xray image. Current research includes 2D/3D registration to match the xray image of the pelvis with the synthetic projection of the CT-scan, in order to precisely reconstruct the spatial position of the pelvis at which the xray was taken. This will allow precise and reliable measurements from xrays and create conditions for better analysis of postoperative outcomes.
Personnel [Past Members]
Publications
Note: This list may not be comprehensive. It contains only those publications in the RI publications database. Entries are listed in reverse chronological order.
- Accuracy of Pelvic Flexion Measurements from Lateral Radiographs
K. Eckman, M.A. Hafez, B. Jaramaz, T.J. Levison, and A.M. Di Gioia, III, MD
Clinical Orthopaedics and Related Research, No. 451, October, 2006, pp. 154 - 160.
- Pelvic landmark localization and cup placement accuracy in virtual fluoroscopy
K. Eckman, A. Mor, D. Davidson, B. Jaramaz, and A.M. Di Gioia, III, MD
Accepted for The 51st Annual Meeting of the Orthopaedic Research Society, 2005.
- Xalign validiation: accurately recovering implant pose from a single anteroposterior radiograph
K. Eckman, A. Mor, B. Jaramaz, and A.M. Di Gioia, III, MD
Accepted for The 51st Annual Meeting of the Orthopaedic Research Society, 2005.
- Accurate single x-ray implant measurements
K. Eckman, A. Mor, and B. Jaramaz
The 4th Annual Conference of the International Society for Computer Assisted Orthopaedic Surgery, 2004.
- Measurements of acetabular cup alignment after total hip arthoplasty using ct/x-ray matching
S. Blendea, K. Eckman, B. Jaramaz, T. Levison, and A.M. Di Gioia, III, MD
The 4th Annual Conference of the International Society for Computer Assisted Orthopaedic Surgery, 2004.
- Pelvic localization errors in virtual fluoroscopy and their impact on cup placement
K. Eckman, A. Mor, D. Davidson, and B. Jaramaz
The 4th Annual Conference of the International Society for Computer Assisted Orthopaedic Surgery, 2004.